RWT Results 2022 Q4

Covered by this topic

General Information

Plan Report ID Number
Developer Name Medical Informatics Engineering
Product Name(s) WebChart EHR
Version Number(s) 8.4
Certified Health IT Product List ID(s) 15.04.04.1932.WebC.74.00.0.181219
Developer Real World Testing Page URL https://docs.webchartnow.com/resources/system-specifications/ehr-certification/real-world-testing/
Plan Submission Date 11/15/2021
Results Version Q4, completed 01/15/2023

Certification Criteria to be Tested

  • ‘‘Transitions of care" (§ 170.315(b)(1) Cures Update);
  • “Clinical information reconciliation and incorporation” (§ 170.315(b)(2));
  • “Electronic prescribing” (§ 170.315(b)(3) Cures Update);
  • “Data export” (§ 170.315(b)(6));
  • “CQMs – record and export” (§ 170.315(c)(1));
  • “CQMs – import and calculate” (§ 170.315(c)(2));
  • “CQMs – report” (§ 170.315(c)(3));
  • “View, download, and transmit to 3rd party” (§ 170.315(e)(1));
  • “Transmission to immunization registries” (§ 170.315(f)(1));
  • “Application access – patient selection” (§ 170.315(g)(7));
  • “Application access – data category request” (§ 170.315(g)(8));
  • “Application access—all data request” (§ 170.315(g)(9) Cures Update);
  • “Direct Project” (§ 170.315(h)(1))

Criteria-Measure Matrix

Criteria Requirement Measure
"Transitions of care" (§170.315(b)(1)) (b)(1)(i)(A)(Alternative) - Send Using Edge Protocol for SMTP/IXE XDR 17
(b)(1)(i)(B)(Alternative) - Receive Using Edge Protocol for SMTP/IXE XDR 17
(b)(1)(i)(C)(Conditional) - XDM Processing 17
(b)(1)(ii)(A) - Receive, Parse, and Process 7, 19
(b)(1)(ii)(B) - View 7
(b)(1)(ii)(C) - Section Display 7
(b)(1)(iii) - Create 7
(b)(1)(iii)(A) - Assessment, Plan, Goals, Health Concerns 7
(b)(1)(iii)(B) - Diagnoses 7
(b)(1)(iii)(C) - Cognitive Status 7
(b)(1)(iii)(D) - Functional Status 7
(b)(1)(iii)(E) - Ambulatory Referral Summary 7
(b)(1)(iii)(F) - Inpatient Discharge Instructions 7
(b)(1)(iii)(G) - Patient Matching 7
"Clinical information reconciliation and incorporation" (§170.315(b)(2)) (b)(2)(ii) - Correct Patient 7
(b)(2)(iii)(A) - Simultaneous Display 9
(b)(2)(iii)(B) - Reconciled List 9
(b)(2)(iii)(C) - User Review 9
(b)(2)(iii)(D) - List Acceptance 9
(b)(2)(iv) - CCD Creation 9
"Electronic prescribing" (§170.315(b)(3)) (b)(3)(ii)(A)(1) - NewRx 3
(b)(3)(ii)(A)(2) - RxChangeRequest, RxChangeResponse 3
(b)(3)(ii)(A)(3) - CancelRx, CancelRxResponse 3
(b)(3)(ii)(A)(4) - RxRenewalRequest, RxRenewalResponse 3
(b)(3)(ii)(A)(5) - RxFill 3
(b)(3)(ii)(A)(6) - RxHistoryRequest, RxHistoryResponse 3
(b)(3)(ii)(A)(7) - Status 3
(b)(3)(ii)(A)(8) - Error 3
(b)(3)(ii)(A)(9) - Verify 3
(b)(3)(ii)(C)(1) - Primary/Secondary Diagnosis 4
(b)(3)(ii)(E) - Metric Units 5
(b)(3)(ii)(F) - Decimal Format 6
"Data export" (§170.315(b)(6)) (b)(6)(i) - Configure and export 18
(b)(6)(ii) - Set Export 18, 19
(b)(6)(ii)(A) - CCDS 18, 19
(b)(6)(ii)(B) - Diagnoses 18, 19
(b)(6)(ii)(C) - Cognitive Status 18, 19
(b)(6)(ii)(D) - Functional Status 18, 19
(b)(6)(ii)(E) - Ambulatory Reason for Referral 18, 19
(b)(6)(ii)(F) - Inpatient Discharge Instructions 18, 19
(b)(6)(iii)(A) - Timeframe configuration 18
(b)(6)(iii)(B) - Export summary 18
(b)(6)(iv) - Save location 18
"CQMs – record and export" (§170.315(c)(1)) (c )(1)(i) - Report 1
(c )(1)(ii) - Export 1
"CQMs – import and calculate" (§170.315(c)(2)) (c )(2)(i) - Import 2
(c )(2)(ii) - Calculate 1, 2
"CQMs – report" (§170.315(c)(3)) (c )(3)(i) - Report 1, 2
"View, download, and transmit to 3rd party" (§170.315(e)(1)) (e)(1)(i) - Web Content Accessibility 21
(e)(1)(i)(A) - View 14
(e)(1)(i)(A)(1) - CCDS 14
(e)(1)(i)(A)(2) - Ambulatory Contact Info 14
(e)(1)(i)(A)(3) - Inpatient Discharge Instructions 14
(e)(1)(i)(A)(4) - Lab Report 14
(e)(1)(i)(A)(5) - Diagnostic Imaging Report 14
(e)(1)(i)(B)(1)(i) - Download Human Readable 15
(e)(1)(i)(B)(1)(ii) - Download CCD 15
(e)(1)(i)(B)(2) - CCD Human Readable 15
(e)(1)(i)(B)(3) - Inpatient Summary 15
(e)(1)(i)(C)(1)(i) - Email 16
(e)(1)(i)(C)(1)(ii) - Encrypted Transmission 16
(e)(1)(i)(C)(2) - Inpatient Email 16
(e)(1)(i)(D)(1) - Specific Date 14, 15, 16
(e)(1)(i)(D)(2) - Date Range 14, 15, 16
(e)(1)(ii)(A) - Activity Log 14, 15, 16
"Transmission to immunization registries" (§170.315(f)(1)) (f)(1)(i) - Create Content 10
(f)(1)(ii) - Query Records 11
"Application access – patient selection" (§170.315(g)(7)) (g)(7)(i) - Query processing and response 20
(g)(7)(ii)(A)(1) - Functional Documentation 8
(g)(7)(ii)(A)(2) - Implementation Requirements 8
(g)(7)(ii)(A)(3) - Terms of Use 8
(g)(7)(ii)(B) - Public Link 8
"Application access – data category request" (§170.315(g)(8)) (g)(8)(i)(A) - Return CCDS data 20
(g)(8)(i)(B) - Request response 20
(g)(8)(ii)(A)(1) - Documentation 8
(g)(8)(ii)(A)(2) - Implementation Requirements 8
(g)(8)(ii)(A)(3) - Terms of Use 8
(g)(8)(ii)(B) - Public URL 8
"Application access—all data request" (§170.315(g)(9)) (g)(9)(i)(A)(1) - Demonstrate API 20
(g)(9)(i)(A)(3) - Data Classes 20
(g)(9)(i)(B) - Data Return 20
(g)(9)(ii)(A)(i) - Documentation 8
(g)(9)(ii)(A)(ii) - Implementation Requirements 8
(g)(9)(ii)(B) - Public URL 8
"Direct Project" (§170.315(h)(1)) (h)(1)(i) - Send 12
(h)(1)(i) - Receive 13
(h)(1)(ii) - Message Disposition Notification: Processed 12
(h)(1)(ii) - Message Disposition Notification: Failed 12

Justification for Real World Testing Approach

WebChart EHR is a cloud-based, fully-inclusive EHR solution. All certified functionality is delivered in all instances of the product regardless of the care setting, size of practice, or required use cases for a given practice. Each production client is maintained in a separate database; however, the implementation of the environment is identical with the exception of optional increased security protocols that a client may choose to add for enhanced data protection. Additionally, the only differences between the client-facing portion of each system are a result of configuration settings that can be selected at go-live or updated at any time during a client’s contract. Due to this philosophy of product delivery, all certified capabilities may not be actively used in all marketed care settings or may not be actively used in any current client production system. To address the Real World Testing requirements, MIE will be using a hybrid approach. Testing will primarily be conducted using de-identified real patient data from production systems as recorded in database tables and log files. For those criteria for which this live production recording is not available or minimal due to lack of client usage, client reported issues will be tracked and reported in addition to enacting automated tests of the certified functionality in a test system in a production environment. The automated tests will be run daily or weekly as appropriate in a system that is identical in substance and delivery to a client production system with the only exception being live real patient data. This blended approach will allow MIE to prove ongoing maintenance of WebChart EHR’s certified technology regardless of the level of implementation by current clients.

Measures Used in Overall Approach

The following measures outline and justify how each requirement of all criteria to which WebChart EHR is certified will be tested during the 2022 Real World Testing year. Please review the Criteria-Measure Matrix above to review which measure(s) will cover a specific requirement.

Measure 1: Clinical Quality Measures Outgoing

Description

This measure will review WebChart EHR’s ability to measure clinical quality and export the required information. Compliance will be tested both manually by developers and clients as well as automatically by reporting bodies and the Cypress CUV+ test system.

Associated Certification Criteria

Certification Criteria Requirement(s)
"CQMs – record and export" (§170.315(c)(1)) (c )(1)(i) - Record
(c )(1)(ii) - Export
"CQMs – import and calculate" (§170.315(c)(2)) (c )(2)(ii) - Calculate
"CQMs – report" (§170.315(c)(3)) (c )(3)(i) - Report

Test Methodology

First, MIE will install an instance of Cypress 6+ on our production servers following all of our protocols for maintaining the security of PHI. Cypress CUV+ supports the validation of QRDA reports containing PHI and will be used monthly to validate a random selection of QRDAs from the care settings identified. Any errors identified by Cypress CUV+ will be tracked, reported, and addressed, then followed with testing of a larger sample of files.

Additionally, WebChart EHR has two customers that participate in quarterly attestations using both QRDA I and QRDA III reports. These customers regularly inspect their CQM compliance numbers and will alert MIE to any perceived errors. MIE will then collect and track the attestation results from the reporting bodies including any errors so as to report a success/failure rate.

Results

Calculations QRDA I QRDA III
Client Reported Issues 0 0 0
Submitted Files N/A 2606 0
Submission Errors N/A 0 0
Tested Files N/A 687 12
Testing Errors N/A 0 0

Discussion

As expected, no errors were found in formatting or coding of the certified measures.

Measure 2: Clinical Quality Measures Incoming

Description

This measure will review WebChart EHR’s ability to measure clinical quality and export the required information. Compliance will be tested both manually by developers and clients as well as automatically by reporting bodies and the Cypress CUV+ test system.

Associated Certification Criteria

Certification Criteria Requirement(s)
"CQMs – import and calculate" (§170.315(c)(2)) (c )(2)(i) - Import
(c )(2)(ii) - Calculate
"CQMs – report" (§170.315(c)(3)) (c )(3)(i) - Report

Test Methodology

MIE will install an instance of Cypress 6+ on our production servers following all of our protocols for maintaining the security of PHI. Automated testing will download QRDA I files from Cypress for each certified CQM, import the files to WebChart EHR, calculate the CQMs, and export the QRDA files for Cypress validation of both the content and calculations to verify that the import was successful. Any errors identified by Cypress will be tracked, reported, and addressed.

Results

QRDA I QRDA III
Tested Files 702 12
Testing Errors 0 0

Discussion

As expected, no errors were found in formatting or coding of the certified measures.

Measure 3: E-Prescribing Messages Sent and Received

Description

This measure will verify that all supported e-prescribing message types are in use in WebChart EHR, including inbound and outbound message types.

Associated Certification Criteria

Certification Criteria Requirement(s)
"Electronic prescribing" (§170.315(b)(3)) (b)(3)(ii)(A)(1) - NewRx
(b)(3)(ii)(A)(2) - RxChangeRequest, RxChangeResponse
(b)(3)(ii)(A)(3) - CancelRx, CancelRxResponse
(b)(3)(ii)(A)(4) - RxRenewalRequest, RxRenewalResponse
(b)(3)(ii)(A)(5) - RxFill
(b)(3)(ii)(A)(6) - RxHistoryRequest, RxHistoryResponse
(b)(3)(ii)(A)(7) - Status
(b)(3)(ii)(A)(8) - Error
(b)(3)(ii)(A)(9) - Verify

Test Methodology

MIE will report a count of messages for each supported message type:

  • NewRx
  • RxChangeRequest
  • RxChangeResponse
  • CancelRx
  • CancelRxResponse
  • RxRenewalRequest
  • RxRenewalResponse
  • RxFill
  • RxHistoryRequest
  • RxHistoryResponse
  • Status
  • Error
  • Verify

The report will also include a count of outbound messages unable to be transmitted due to connectivity issues or other errors, for each message type. This report will be based on the contents of each client’s local database table of stored messages. MIE will run the report for each client under consideration and aggregate the results.

Results

Message Type Client Message Counts Total Count
NewRx 11600 56016 30346 8832 2497 109291
RxChangeRequest 14 114 568 173 0 869
RxChangeResponse 2 115 467 173 0 757
CancelRx 80 101 3 1 1 186
CancelRxReponse 74 72 2 1 1 150
RxRenewalRequest 3450 3103 14049 1783 0 22385
RxRenewalResponse 3151 3063 12932 1783 0 20929
RxFill 0 0 0 406 0 406
RxHistoryRequest 0 0 0 0 0 0
RxHistoryResponse 0 0 0 0 0 0
Status 30418 108524 94524 21853 4680 259999
Error 143 561 487 58 3 1252
Verify 12167 46417 36230 8716 2191 105721
Error Text Total Count
(Error Code: 600) 2
(Error Code: 601) (Desc. Code: 008) 54
(Error Code: 900) 16
1 errors validating against transport.xsd 'Address' has invalid child element 'City'. List of possible elements expected: 'AddressLine1'. (Error Code: 900) 9
1 errors validating against transport.xsd 'Address' has invalid child element 'PostalCode'. List of possible elements expected: 'StateProvince'. (Error Code: 900) 2
1 errors validating against transport.xsd 'Address' has invalid child element 'StateProvince'. List of possible elements expected: 'AddressLine1'. (Error Code: 900) 12
1 errors validating against transport.xsd 'Address' has invalid child element 'StateProvince'. List of possible elements expected: 'AddressLine2, City'. (Error Code: 900) 3
1 errors validating against transport.xsd 'MedicationPrescribed' has incomplete content. List of possible elements expected: 'DrugUseEvaluation, DrugCoverageStatusCode, PriorAuthorizationStatus, Sig'. (Error Code: 900) 1
1 errors validating against transport.xsd 'MedicationPrescribed' has invalid child element 'DaysSupply'. List of possible elements expected: 'Quantity'. (Error Code: 900) 5
1 errors validating against transport.xsd 'MedicationPrescribed' has invalid child element 'WrittenDate'. List of possible elements expected: 'Quantity'. (Error Code: 900) 29
1 errors validating against transport.xsd 'Sig' has incomplete content. List of possible elements expected: 'SigText'. (Error Code: 900) 1
1 errors validating against transport.xsd The 'AddressLine1' element is invalid - The value '5633 SOUTH WAYNE AVE APT D' is invalid according to its datatype 'an1..40' - The Pattern constraint failed. (Error Code: 900) 1
1 errors validating against transport.xsd The 'AddressLine1' element is invalid - The value '5633 SOUTH WAYNE AVE APT. D' is invalid according to its datatype 'an1..40' - The Pattern constraint failed. (Error Code: 900) 2
1 errors validating against transport.xsd The 'DaysSupply' element is invalid - The value '2970' is invalid according to its datatype 'n1..3' - The actual length is greater than the MaxLength value. (Error Code: 900) 2
1 errors validating against transport.xsd The 'DrugDescription' element is invalid - The value '' is invalid according to its datatype 'an1..105' - The Pattern constraint failed. (Error Code: 900) 2
1 errors validating against transport.xsd The 'Extension' element is invalid - The value '2606735445' is invalid according to its datatype 'n1..8' - The actual length is greater than the MaxLength value. (Error Code: 900) 1
1 errors validating against transport.xsd The 'Note' element is invalid - The value ' 3 3 @' is invalid according to its datatype 'an1..210' - The Pattern constraint failed. (Error Code: 900) 1
1 errors validating against transport.xsd The 'Note' element is invalid - The value ' Information regarding your request; Drug is covered by current benefit plan. No further PA activity needed' is invalid according to its datatype 'an1..210' - The Pattern constraint failed. (Error Code: 900) 1
1 errors validating against transport.xsd The 'Note' element is invalid - The value 'G ; 2 ; W ; ; { ; ; ; ; $ ;' is invalid according to its datatype 'an1..210' - The Pattern constraint failed. (Error Code: 900) 1
1 errors validating against transport.xsd The 'Note' element is invalid - The value 'Per UpToDate Guidance: Infants 9 months: Oral: 3.5 mg/kg/dose twice daily' is invalid according to its datatype 'an1..210' - The Pattern constraint failed. (Error Code: 900) 1
1 errors validating against transport.xsd The 'Note' element is invalid - The value 'Type 2 diabetes mellitus with hyperglycemia, without long-term current use of insulin E11.65' is invalid according to its datatype 'an1..70' - The actual length is greater than the MaxLength value. (Error Code: 900) 1
1 errors validating against transport.xsd The 'Note' element is invalid - The value 'this was sent to Longs 6/7:; ID 619a21f6897247a9-abe8709427acd660; Date 06-07-2021 by Sarah R Kaplan; Prescriber Sarah R Kaplan; To Longs Drug Store #9663 - 70 E Kaahumanu Ave Kahului HI (808) 877-0068 f: (808)' is invalid according to its datatype 'an1..210' - The Pattern constraint failed. (Error Code: 900) 1
1 errors validating against transport.xsd The 'Number' element is invalid - The value '12605873288' is invalid according to its datatype 'n1..10' - The actual length is greater than the MaxLength value. (Error Code: 900) 2
1 errors validating against transport.xsd The 'Number' element is invalid - The value '26022339862' is invalid according to its datatype 'n1..10' - The actual length is greater than the MaxLength value. (Error Code: 900) 2
1 errors validating against transport.xsd The 'Number' element is invalid - The value '26086711166' is invalid according to its datatype 'n1..10' - The actual length is greater than the MaxLength value. (Error Code: 900) 9
1 errors validating against transport.xsd The 'Number' element is invalid - The value '41923800944' is invalid according to its datatype 'n1..10' - The actual length is greater than the MaxLength value. (Error Code: 900) 7
1 errors validating against transport.xsd The 'Number' element is invalid - The value '41963396028' is invalid according to its datatype 'n1..10' - The actual length is greater than the MaxLength value. (Error Code: 900) 10
1 errors validating against transport.xsd The 'NumberOfRefills' element is invalid - The value '180' is invalid according to its datatype 'n1..2' - The actual length is greater than the MaxLength value. (Error Code: 900) 3
1 errors validating against transport.xsd The 'StateProvince' element is invalid - The value '' is invalid according to its datatype 'an' - The Pattern constraint failed. (Error Code: 900) 7
Cannot get endpoint (id = 6505404965001 uid = 1), please contact support (Error Code: 602) 1
Cannot get endpoint (id = 6888514521004 uid = 1), please contact support (Error Code: 602) 1
Cannot get endpoint (id = 6989612455001 uid = 1), please contact support (Error Code: 602) 1
Controlled substance must be signed or Digital Signature Indicator must be true. (Error Code: 900) 6
Controlled substance must have a DEASchedule populated in Medication Prescribed (Error Code: 900) 11
DEA or SSN not found in the message (Error Code: 900) 17
ERX611 ERROR PROCESSING MESSAGE TO RECIPIENT (Error Code: 600) (Desc. Code: 4000) 2
Fax receipt could not be confirmed (Error Code: 600) 2
Intermediary system error. (Error Code: 900) (Desc. Code: 4020) 18
Internal error.Contact pharmacy by other means. (Error Code: 600) (Desc. Code: 008) 4
MAIL-PREVIOUS RESPONSE HAS BEEN PROCESSED. THIS WILL NOT BE ACCEPTED (Error Code: 602) 6
Mailboxed message could not be confirmed after three tries (Error Code: 602) 1
Message is a duplicate. 113
Message type not supported by sender (Error Code: 900) 1
NewRx MedicationPrescribed Quantity must be a non-zero value (Error Code: 900) 23
No NDC or compound or supply code in message for MedicationPrescribed (Error Code: 900) 14
No NDC or compound or supply code in message for MedicationResponse (Error Code: 900) 1
Partner rejected transaction with an error (Error Code: 900) (Desc. Code: 220) 18
Pharmacy is temporarily down. Please retry. (Error Code: 900) (Desc. Code: 2000) 41
Pharmacy record inactive, may have new active location (Error Code: 900) 2
Prescriber address required for controlled substance (Error Code: 900) 1
PrescriberOrderNumber must be present and populated (Error Code: 900) 1
Prescription no longer active (Error Code: 601) 101
Receiving partner does not support this type of message (Error Code: 900) 26
Refill request has been canceled (Error Code: 900) (Desc. Code: 4020) 7
Request has been canceled prior to response. Response not processed. (Error Code: 601) (Desc. Code: 008) 38
SCRIPT Validation Error: See free text for description (Error Code: 900) 3
Storage error. (Error Code: 602) 1
The MedicationPrescribed QuantityUnitOfMeasure Code: C16830 is invalid (Error Code: 900) 3
The MedicationPrescribed QuantityUnitOfMeasure Code: C28253 is invalid (Error Code: 900) 4
The MedicationPrescribed QuantityUnitOfMeasure Code: C48477 is invalid (Error Code: 900) 6
The MedicationPrescribed QuantityUnitOfMeasure Code: C48478 is invalid (Error Code: 900) 8
The MedicationPrescribed QuantityUnitOfMeasure Code: C48481 is invalid (Error Code: 900) 1
The MedicationPrescribed QuantityUnitOfMeasure Code: C48519 is invalid (Error Code: 900) 1
The MedicationPrescribed QuantityUnitOfMeasure Code: C48537 is invalid (Error Code: 900) 1
The MedicationPrescribed QuantityUnitOfMeasure Code: C48540 is invalid (Error Code: 900) 110
The MedicationPrescribed QuantityUnitOfMeasure Code: C48549 is invalid (Error Code: 900) 4
The MedicationPrescribed QuantityUnitOfMeasure Code: C48551 is invalid (Error Code: 900) 403
The MedicationPrescribed QuantityUnitOfMeasure Code: C62275 is invalid (Error Code: 900) 48
The MedicationPrescribed QuantityUnitOfMeasure Code: C97717 is invalid (Error Code: 900) 6
Unable to associate Response to Request (Error Code: 601) 1
Unexpected Exception occured while processing the request. (Error Code: 900) 2

Total error rate: 1252/521945*100 = 0.24%

Discussion

As expected, all supported message types have a greater than zero total message count, and the total number of messages far exceeds the number of errored messages with a total error rate of 0.24% .This represents a decrease in both the total number or errored messages and overall error rate from Q3. Additionally, the number of NewRx messages is significantly greater than the number of RxChangeResponse, CancelRx, and RxRenewalResponse messages.

Measure 4: E-Prescribing Diagnosis Codes

Description

This measure will verify that all diagnosis elements are present in some e-prescribing messages as required by §170.315(b)(3), including inbound and outbound message types.

Associated Certification Criteria

Certification Criteria Requirement(s)
"Electronic prescribing" (§170.315(b)(3)) (b)(3)(ii)(C)(1) - Primary/Secondary Diagnosis

Test Methodology

MIE will report the contents of each stored message in a client’s local database table of stored messages, and counts the inbound and outbound messages that include Diagnosis elements. MIE will run the report for each client under consideration and aggregate the results.

Results

Total NewRx Messages NewRx Messages with Diagnosis Included
109291 34056

Discussion

Since the Diagnosis elements are not a required component of a NewRx message, as anticipated, only a subset (31.16%) of the NewRx messages included a diagnosis; however, this is an increase in diagnosis usage over the 29.65% of Q3.

Measure 5: E-Prescribing Oral Liquid Units

Description

This measure will verify that prescriptions for medications with an oral liquid form will have a quantity unit of measurement of mL, not cc or English units as outlined in §170.315(b)(3).

Associated Certification Criteria

Certification Criteria Requirement(s)
"Electronic prescribing" (§170.315(b)(3)) (b)(3)(ii)(E) - Metric Units

Test Methodology

MIE will create a system report that examines the contents of each stored NewRx message in a client’s local database table of stored messages, limiting to oral liquid medications, and provides a count of each distinct quantity unit of measure used. MIE will run the report for each client under consideration and aggregate the results.

Results

Unit Code Unit Description Quantity
C28254 Milliliter (ml) 4393
C64933 Each 2
C48477 Bottle 0
C48521 Packet 2
C48542 Tablet 1

Units of Presentation

Discussion

As expected, C28254 (milliliters) is the most commonly sent unit of measure for oral liquid medications. Non-C28254 units were only sent in 0.11% of oral liquid medication messages. This represents an increase in incorrect code usage from Q2.

Measure 6: E-Prescribing Decimal Format

Description

This measure will verify that numeric amounts in prescriptions include leading zeros before decimal points and do not allow trailing zeros after a decimal point.

Associated Certification Criteria

Certification Criteria Requirement(s)
"Electronic prescribing" (§170.315(b)(3)) (b)(3)(ii)(F) - Decimal Format

Test Methodology

MIE will create a system report that examines the contents of each stored NewRx message in a client’s local database table of stored messages, and provides a count of prescription messages that include inappropriate trailing zeros, and a count of those missing leading zeros. MIE will run the report for each client under consideration and aggregate the results.

Results

Total NewRx Messages NewRx Messages with Improper Decimal Format
109291 584

Discussion

As expected, the number of NewRx messages sent with inappropriate trailing zeros, or missing leading zeros, occurs rarely in only 0.53% of messages; however, this represents an increase from Q3 which indicates the need for either client education or coded validation in the software.

Measure 7: CDA Download

Description

This measure will verify that the system can accept a CDA document uploaded into the system, assign it to the appropriate chart in the system as appropriate, and display the document with a standard stylesheet with all sections being accepted and visible.

Associated Certification Criteria

Certification Criteria Requirement(s)
"Clinical information reconciliation and incorporation" (§ 170.315(b)(2)) (b)(2)(ii) - Correct patient.
‘‘Transitions of care" (§ 170.315(b)(1)) (b)(1)(ii) - All paragraphs
(b)(1)(iii) - All paragraphs

Test Methodology

MIE will report on the number of CDA formatted documents uploaded into tracked Webchart systems and the number of upload attempts that failed as stored in client databases and error log files.

MIE will report on the number of requests to view a CDA document within the system, and the number of times it displayed correctly, and when there were errors in display.
Any errors reported by customers or the recipients of their quarterly attestations will be tracked and reported as a baseline. These test assumptions for customer reporting align with the “visual inspection” aspects of the test lab tests.

Results

Total CDA Documents Uploaded 23,760
Total CDA Document Upload Failures 0
Total CDA Document Views 5,066
Total CDA Document View Reported Errors 0
Total Successful CDA Views 5,066

Discussion

As anticipated, there were no errors in being able to upload and view valid CCDA documents. More documents were uploaded/created and viewed in Q4 than Q3.

Measure 8: Application Access Documentation

Description

This measure will verify that WebChart EHR’s API documentation is publicly and perpetually available. Compliance will be recorded by an external uptime monitor and reported quarterly. Upon request, or in the event of downtime, data can additionally be reported in daily, weekly, or monthly increments.

Associated Certification Criteria

Certification Criteria Requirement(s)
"Application access – patient selection" (§ 170.315(g)(7)) (g)(7)(ii)(A)(1) - Functional Documentation
(g)(7)(ii)(A)(2) - Implementation Requirements
(g)(7)(ii)(A)(3) - Terms of Use
(g)(7)(ii)(B) - Public Link
"Application access – data category request" (§ 170.315(g)(8)) (g)(8)(ii)(A)(1) - Documentation
(g)(8)(ii)(A)(2) - Implementation Requirements
(g)(8)(ii)(A)(3) - Terms of Use
(g)(8)(ii)(B) - Public URL
"Application access—all data request" (§ 170.315(g)(9)) (g)(9)(ii)(A)(i) - Documentation
(g)(9)(ii)(A)(ii) - Implementation Requirements
(g)(9)(ii)(B) - Public URL

Test Methodology

An external uptime monitor will check the availability of all documentation available at https://docs.webchartnow.com/resources/system-specifications/application-programming-interface-api.html. Both up- and downtime will be logged to be reported quarterly. The cause of any downtime and the duration will also be logged In the event of any downtime, the amount of downtime can be reported at daily, weekly, or monthly intervals in addition to the quarterly reports, and the cause of each downtime occurrence will be reported.

Results

The MIE API documentation was available 99.967% of Q4.

Three instances of prolonged downtime occurred:

10/14/2022: 13 minutes

10/27/2022: 5 minutes

12/6/2022: 25 minutes

Discussion

As expected, the documentation maintained an uptime of greater than 99.9% at 99.967% for the quarter.

Measure 9: Clinical Information Reconciliation and Incorporation

Description

This measure will verify that the system can take a CCDA transition of care/referral summary formatted according to the standards adopted §170.205(a)(3) and §170.205(a)(4) and read the data for medications, allergies, and conditions from the document, reconcile those into the chart, and that the data is fully incorporated into the chart.

Associated Certification Criteria

Certification Criteria Requirement(s)
"Clinical information reconciliation and incorporation" (§ 170.315(b)(2)) (b)(2)(iii)(A), (B), (C), (D)
(b)(2)(iv) - System Verification

Test Methodology

MIE will report on the number of CDA formatted documents reconciled via the “Froozhie” tool.

Following each reconcile, a temporary CDA for the chart will be created and validated to ensure the reconciled data can be incorporated into a CDA created free of schematic errors (the CDA document will NOT be kept, only the result of the validation). Additionally, any client complaints that data is not being imported correctly from the tool will be tracked, investigated, and reported

Results

CDA Documents Reconciled 3
CDA Documents Generated on a Chart after a Reconcile that had an invalid Validation 1
Client reported Issues with CDA reconciliation 0

Discussion

The use of CDA reconciliation in systems was extremely low compared to Q3, and no issues with the reconciliation of the documents were reported. The drop-off was because of a lack of reconciliations from the specific client that was the source of most reconciliations in previous quarters.

Further work was done near the end of Q4 on CCDA generation being error free, and we anticipate less invalid CCDAs in future quarters.

Measure 10: Transmission to Immunization Registry: Create Content

Description

This measure will verify that the system can generate a VXU conforming to the HL7 v2.5.1 standard, CDC guidance for communication to Immunization Registries and state/local guidance. The VXU messages shall contain information related to the demographics and vaccination administration record.

Associated Certification Criteria

Certification Criteria Requirement(s)
"Transmission to immunization registries" (§ 170.315(f)(1)) (f)(1)(i) - Create Content

Test Methodology

MIE will report from the database the number of successfully sent VXU messages acknowledged as received by the state immunization registry. MIE will also report from the database on the number of records rejected by the state registry due to error, whether the failure was due to registry internal errors, clinical data entry issues or a not well-formed message. Finally, MIE will report from the database the number of messages which declined to be generated due to data entry issues failing message pre-validation.

Results

Successful transmission to registry 4867
Rejected by the registry 1
Declined to generate 6

Discussion

As expected, very few messages were rejected by the state registry. There is a small portion of the entered injections which were not able to be transmitted to the state registry due to user data entry issues.

Measure 11: Transmission to Immunization Registries: Query Records

Description

This measure will verify that the system can generate a QBP conforming to the HL7 v2.5.1 standard, CDC guidance for communication to Immunization Registries and state/local guidance. Furthermore, the system shall be able to retrieve, consume and display to the end user the results of any such query.

Associated Certification Criteria

Certification Criteria Requirement(s)
"Transmission to immunization registries" (§ 170.315(f)(1)) f)(1)(ii) - Query Records

Test Methodology

MIE will report the number of successful retrievals of evaluated history and forecasting operations from the database. MIE will report the number of failed retrievals, including those resulting from an internal error in the registry resulting in an inability to consume a response from the database. MIE will manually track, resolve and report issues resulting from WebChart EHR application errors as reported by end users.

Results

Successful retrievals 9326
Failed retrievals 128

Discussion

As expected, most of the queries were successful.

Measure 12: Direct Project: Send

Description

This measure will verify that the system can transmit a Direct project conforming S/MIME to a HISP. The measure will also verify the receipt of those transmissions by verifying the status of the resultant MDN messages.

Associated Certification Criteria

Certification Criteria Requirement(s)
"Direct Project" (§ 170.315(h)(1)) (h)(1)(i) - Send
(h)(1)(ii) - Message Disposition Notification: Processed
(h)(1)(ii) - Message Disposition Notification: Failed

Test Methodology

MIE will report from log files the number of messages transmitted. MIE will report from logs the number of messages which failed to be transmitted whether due to internal error, external failures or inability to verify trust of the recipient. MIE will report from logs the number of Processed MDN messages received. MIE will report from logs the number of Failed MDN messages received.

Results

Messages Transmitted 0
Failed to transmit 0
Failed MDNs received 0

Discussion

This quarter was one of very limited usage.

Measure 13: Direct Project: Receive

Description

This measure will verify that the system conforms to Direct Project message receipt requirements for validation.

Associated Certification Criteria

Certification Criteria Requirement(s)
"Direct Project" (§ 170.315(h)(1)) (h)(1)(i) - Receive

Test Methodology

MIE will report from logs the number of messages transmitted to the HISP. MIE will report from logs the number of messages failing to conform to Direct Project specifications. MIE will report from logs the number of messages which are successfully delivered to recipients.

Results

Messages received by HISP 0
Messages failing to conform 0
Messages successfully delivered 0

Discussion

This quarter was one of very limited usage.

Measure 14: Patient Portal View

Description

This measure will verify that a patient can view various document types within the patient portal.

Associated Certification Criteria

Certification Criteria Requirement(s)
"View, download, and transmit to 3rd party" (§ 170.315(e)(1)) (e)(1)(i)(A)(1),(2),(3),(4),(5)
(e)(1)(i)(D)(1), (2)
(e)(1)(ii)(A)

Test Methodology

MIE will report a number of measurements surrounding documents, including:

  • Number of documents sent successfully to patients in the patient portal
  • Number of documents unsuccessfully sent to the patient portal
  • Number of documents read by patients in the patient portal
  • Number of failures in the ability to read messages in the patient portal

Results will be retrieved from database tables and aggregated for reporting. Any failures will be reported from the information found in log files as well as any client reported issues tracked during the testing period.

Results

CDA/Other Documents Sent to the patient portal 0
CDA/Other Documents Unsuccessfully Sent to the patient portal 0
CDA/Other Documents Read by Patients in the Patient Portal 0
CDA/Other Documents Failed to be read in the Patient Portal 0

Discussion

During the fourth quarter, no tracked clients were sending CDA documents into the patient portal. Additional testing as well as client education will be investigated to provide more robust data in future quarters.

Measure 15: Patient Portal Download

Description

This measure will verify that a patient can download various document types within the patient portal.

Associated Certification Criteria

Certification Criteria Requirement(s)
"View, download, and transmit to 3rd party" (§ 170.315(e)(1)) (e)(1)(i)(B)(1), (2), (3)
(e)(1)(i)(D)(1), (2)
(e)(1)(ii)(A)

Test Methodology

MIE will report a number of measurements surrounding documents, including:

  • Number of documents sent successfully to patients in the patient portal
  • Number of documents unsuccessfully sent to the patient portal
  • Number of documents successfully downloaded from the patient portal
  • Number of documents unsuccessful in being downloaded from the patient portal.

Results will be retrieved from database tables and aggregated for reporting. Any failures will be reported from the information found in log files and third party reports as well as any client reported issues tracked during the testing period.

Results

CDA Documents Sent to the patient portal 0
CDA Documents Unsuccessfully Sent to the patient portal 0
CDA Documents Downloaded by Patients in the Patient Portal 0
CDA Documents Failed to be downloaded in the Patient Portal 0

Discussion

During the fourth quarter, no tracked clients were sending CDA documents into the patient portal. Additional testing as well as client education will be investigated to provide more robust data in future quarters.

Measure 16: Patient Portal CCDA Transmit

Description

This measure will verify that a patient can transmit various document types within the patient portal to other entities.

Associated Certification Criteria

Certification Criteria Requirement(s)
"View, download, and transmit to 3rd party" (§ 170.315(e)(1)) (e)(1)(i)(C)(1), (2)
(e)(1)(i)(D)(1), (2)
(e)(1)(ii)(A)

Test Methodology

MIE will report a number of measurements surrounding documents, including:

  • Number of documents sent successfully to patients in the patient portal
  • Number of documents unsuccessfully sent to the patient portal
  • Number of documents successfully transmitted from the patient portal
  • Number of documents unsuccessful in being transmitted from the patient portal.

Results will be retrieved from database tables and aggregated for reporting. Any failures will be reported from the information found in log files and third party reports as well as any client reported issues tracked during the testing period.

Results

CDA Documents Sent to the patient portal 0
CDA Documents Unsuccessfully Sent to the patient portal 0
CDA Documents Sent by Patients in the Patient Portal 0
CDA Documents Failed to be sent in the Patient Portal 0

Discussion

During the fourth quarter, no tracked clients were sending CDA documents into the patient portal. Additional testing as well as client education will be investigated to provide more robust data in future quarters.

Measure 17: Send Using Edge Protocol for SMTP / XDM

Description

This measure will verify that the system is able to utilize a SMTP edge protocol for sending and receiving Direct Project messages. As part of receiving messages, XDM shall be handled when applicable.

Associated Certification Criteria

Certification Criteria Requirement(s)
‘‘Transitions of care" (§ 170.315(b)(1)) (b)(1)(i)(A)(Alternative) - Send Using Edge Protocol for SMTP/IXE XDR
(b)(1)(i)(B)(Alternative) - Receive Using Edge Protocol for SMTP/IXE XDR
(b)(1)(i)(C)(Conditional) - XDM Processing

Test Methodology

MIE will report from logs the number of messages transmitted to the HISP by SMTP. MIE will report from logs the number of messages received from the HISP by SMTP. MIE will report from logs the number of XDM packages processed. In the case where insufficient real-world data is available, data resulting from regular testing with DirectTrust shall be included in the reporting.

Results

Messages submitted to HISP via SMTP 0
Number of XDM packages processed 129

Discussion

This quarter was one of very little HISP usage. XDM packages that were processed included packages from standard regular testing.

Measure 18: Data Export

Description

This measure will verify that a user can use WebChart EHR’s Data Export Tool to pull down groups of patient data from a Webchart EHR system.

Associated Certification Criteria

Certification Criteria Requirement(s)
"Data export" (§ 170.315(b)(6)) (b)(6)(i)
(b)(6)(ii)(A)-(F)
(b)(6)(iii)(A)-(B)
(b)(6)(iv)

Test Methodology

MIE will report from the event log database tables a series of occurrences that indicates use of the WebChart EHR Data Export Tool:

  • Event logs of the report to find all patients for Document Export being called.
  • Event logs of CDA documents being generated within a certain short time period following the report.

MIE will track customer reports of data expected to be in mass data export downloads that did not download as failures.

Results

Number of times EHR Data Export Tool was used: 0

Discussion

During the fourth quarter, no clients used the EHR Data Export Tool. Additional testing will be investigated to provide more robust data in future quarters.

Measure 19: CDA Validation

Description

This measure will verify that CDAs both created by and received by a Webchart EHR system pass basic CDA validation.

Associated Certification Criteria

Certification Criteria Requirement(s)
‘‘Transitions of care" (§ 170.315(b)(1) Cures Update) (b)(1)(ii)(A)
"Data export" (§ 170.315(b)(6)) (b)(6)(ii), (A)-(F)

Test Methodology

All CDAs stored within a Webchart EHR will be run through schema validation regardless of the document’s origin. Documents may originate within the WebChart EHR system or be imported from a third party application of manual upload. The schema validator will be installed within the MIE production environment to ensure the security of all PHI contained in the documents. Only results of the validation will be made available, document content will not be revealed to developers during testing.

The number of valid vs. invalid CDAs and their sources will be reported.

Results

All CDAs

CDA Documents Marked Valid in Period 124
CDA Documents Marked Invalid in Period 262
% Marked Invalid In Period 67%

Webchart Generated CDAs Only

CDA Documents Marked Valid in Period 1
CDA Documents Marked Invalid in Period 1
% Marked Invalid In Period 50%
#### Discussion

The % marked invalid was high this period, but almost all CDA documents tested were from 3rd parties. As stated in Measure 9, “Work is being done to rectify the issues with the CDA generation in these systems, and to put in place a more immediate notification process when invalid CDAs are generated.” MIE late in the quarter pushed out some updates to improve CDA generation when certain data might be missing and causing CDA validation issues, and anticipate the invalid percentage for to go down in future quarters. We also anticipate in 2023 that we will be generating more CCDA documents within the systems as part of workflow updates in some systems.

Measure 20: Patient Data requests VIA API

Description

This measure will verify that the API as outlined in WebChart EHR’s documentation is functional. A valid request for patient information must provide that information.

Associated Certification Criteria

Certification Criteria Requirement(s)
"Application access – patient selection" (§ 170.315(g)(7)) (g)(7)(i) - Query processing and response
"Application access – data category request" (§ 170.315(g)(8)) (g)(8)(i)(A) - Return CCDS data
(g)(8)(i)(B) - Request response
"Application access—all data request" (§ 170.315(g)(9)) (g)(9)(i)(A)(1) - Demonstrate API
(g)(9)(i)(A)(3) - Data Classes
(g)(9)(i)(B) - Data Return

Test Methodology

To address the overall automated testing, the following test requests will be made daily against a test system in a production environment.

  • Issue a request in the browser to search for a patient (patient selection)
  • Issue a request in the browser to request demographics of a patient (data category request)
  • Issue a request using the export tool described in the documentation.

All API requests made in production systems are recorded in log files. The number of requests logged will be reported against the number of issues with API functionality that are reported.

Results

Production Exports 1
Total Charts Exported 43435
Total Export Errors 1 (ran out of space)

Discussion

As expected, the production use of the API was rare, but the total number of export errors was minimal. Patient chart exports were successful in 99.9% of cases on the first run. The error was corrected and the rest of the data for the charts was exported.

Measure 21: Web Content Accessibility

Description

This measure will verify that all certified content in the patient portal will maintain accessibility conformance as outlined in the Web Content Accessibility Guidelines (WCAG) 2.0.

Associated Certification Criteria

Certification Criteria Requirement(s)
(e)(1)(i) - Web Content Accessibility

Test Methodology

MIE will conduct monthly third-party production accessibility scanning as well as automated nightly internal accessibility scanning of a test system in a production environment.

Results

The internal accessibility scanning of a pre-production test system identified 0 urgent and 0 secondary non-conformance issues in 00.00% of nightly and ad-hoc scans. In the remaining 0.00% of scans only secondary issues were uncovered, all of which were eliminated prior to code changes reaching production systems. Production accessibility scanning identified 0 urgent and 0 secondary non-conformance issues for the entire quarter.

Discussion

As expected no urgent non-conformance issues were identified in either live production or pre-production test systems. In the rare occurrence that a secondary non-conformance issue was identified in testing, it was addressed and eliminated prior to reaching live production systems.

Schedule of Key Milestones

Key Milestone Care Setting Date/Timeframe Status
Release of documentation for the Real World Testing to be provided to ACB and providers All settings Nov 15, 2021 Complete
Begin collection of information as laid out by the plan All settings Jan 1, 2022 Complete and ongoing
New certification of b.7, b.8, b.9 All settings Q1, 2022 Complete
Certification of additional CQMs to c.1, c.2, c.3 and QRDA SVAP All settings Q1, 2022 Complete
Attest to Cures update version of b.2, e.1 All settings Q1, 2022 Complete
Follow-up with providers and authorized representatives to understand any issues arising with the data collection. All settings Quarterly, 2022 Q1, Q2, and Q3 complete
Data collection and review. All settings Quarterly, 2022 Q1, Q2, and Q3 complete
New certification of b.10, g.10 All settings Q3, 2022 G.10 complete
B.10 planned for 2023
End of Real World Testing period/final collection of all data for analysis All settings Dec 31, 2022
Data analysis and report creation All settings January, 2023
Submission of Real World Testing Results to ACB All settings Feb 1, 2023

Attestation

This Real World Testing plan is complete with all required elements, including measures that address all certification criteria and care settings. All information in this plan is up to date and fully addresses the health IT developer’s Real World Testing requirements.

Authorized Representative Name Doug Horner
Authorized Representative Email horner@mieweb.com
Authorized Representative Phone 260-459-6270
Authorized Representative Signature
Date 01/15/2023